Limit Variables

~lt~

Lower tolerance.

~lt2~

Lower tolerance 2.

~lsl~

Lower specification limit. The lower engineering limit specified for a measurement.

~lsl2~

Lower specification limit 2. The lower engineering limit 2 specified for a measurement.

~lrl~

Lower reasonable limit.

~lrt~

Lower reasonable tolerance.

~lcl~

Lower control limit. The lower control limit for control charts. Control limits are used with the distribution of averages not the distribution of individuals. Control limits are used in conjunction with process control charts to identify when assignable causes of variation are present. Control limits should not be confused with specification limits which are established for engineering specifications and are used with individual measurements to indicate process performance.

~lcl,[char],[param]~

 

~lcl2~

Lower Control Limit 2. The variable ~lcl2~ will return the value of the lcl 2 if one has been created. See ~lcl~.

~lcl2,[char],[param]~

 

~lclxbr~

Lower control limit for Xbar with Range.

~lclxbr,[char],[param]~

 

~lclxmr~

Lower control limit for  X with Moving Range.

~lclxmr,[char],[param]~

 

~lclxbs~

Lower control limit for Xbar with Standard Deviation.

~lclxbs,[char],[param]~

 

~lclr~

Lower control limit for Range  

~lclr,[char],[param]~

 

~lcls~

Lower control limit for Standard Deviation  

~lcls,[char],[param]~

 

~lclmr~

Lower control limit for Moving Range  

~lclmr,[char],[param]~

 

~lclma~

Lower control limit for Moving Average  

~lclma,[char],[param]~